Recommendation G.958 Recommendation G.958 DIGITAL LINE SYSTEMS BASED ON THE SYNCHRONOUS DIGITAL HIERARCHY FOR USE ON OPTICAL FIBRE CABLES 1 Introduction 1.1 General The CCITT, considering (a) that Recommendations G.707, G.708 and G.709 specify the bit rates, the multiplexing structure and the detailed mappings associated with the synchronous digital hierarchy (SDH); (b) that Recommendations G.781, G.782, G.783 specify the general characteristics and functions of synchronous multiplexing equipment and Recommendation G.784 the management of SDH equipment and networks; (c) that Recommendations G.703 and G.957 specify the physical parameters of the electrical and optical interfaces of SDH equipment; (d) that Recommendations of Serie G.780 specify SDH multiplexing equipment in terms of functional blocks without any constraint on physical implementation; (e) that among the first generation of SDH equipment there will be synchronous line systems; (f) that there is a need to ensure that these new systems provide longitudinal compatibility with plesiochronous line systems complying with Recommendations G.955 and G.956, recommends that digital synchronous line systems comply with the requirements described in the following. 1.2 Abbreviations ADM Add-drop multiplexer AIS Alarm indication signal ALS Automatic laser shutdown BER Bit error ratio BIP-8 Bit Interleaved parity order 8 CID Consecutive identical digit DCC Data communications channel DXC Digital cross-connect E/O Electrical/optical ECC Embedded control channel I/F Interface LOF Loss of frame MCF Message communications function MS-AIS Multiplex section alarm indication signal styleref head_footRecommendation G.958 PAGE1 MUX Multiplexer NE Network element O/E Optical/electrical OHA Overhead access OOF Out of frame OS/MD Operations system/mediation device PLL Phase locked loop PRBS Pseudo random binary sequence RSOH Regenerator section overhead RST Regenerator section termination RTG Regenerator timing generator SDH Synchronous digital hierarchy SEMF Synchronous equipment management function SMS SDH management subnetwork SOH Section overhead SPI SDH physical interface STM-N Synchronous transport module TMN Telecommunications management network 1.3 Definitions 1.3.1 Agent See Recommendation G.784. 1.3.2 automatic laser shutdown (ALS) The ALS function of an optical line system automatically switches off the transmitter of a regenerator section in case of cable break in this section. 1.3.3 Bit interleaved parity order 8 (BIP-8) See Recommendation G.708. 1.3.4 consecutive identical digit (CID) immunity The ability of a digital system component to sustain the occurrence of a digital signal containing a continuous stream of binary ZEROs or ONEs. 1.3.5 Data communications channel (DCC) See Recommendation G.784. 1.3.6 Embedded control channel (ECC) See Recommendation G.784. 1.3.7 Loss of frame (LOF) See Recommendation G.783. 1.3.8 Message communications function (MCF) See Recommendation G.784. PAGE22 styleref head_footRecommendation G.958 1.3.9 Multiplex section alarm indication signal (MS-AIS) See Recommendation G.783. 1.3.10 Network element (NE) See Recommendation G.784. 1.3.11 Operations system/mediation device (OS/MD) See Recommendation G.784. 1.3.12 Out of frame (OFF) See Recommendation G.783. 1.3.13 Overhead access (OHA) See Recommendation G.783. 1.3.14 Regenerator section overhead (RSOH) See Recommendation G.782. 1.3.15 Regenerator section termination (RST) See Recommendation G.782. 1.3.16 regenerator timing generator (RTG) The RTG function provides a timing reference to the outgoing STM-N signal of a regenerator. This timing reference is derived from the incoming STM-N signal recovered by the SPI function in normal operation, or from an internal oscillator included in the RTG in case of fault. 1.3.17 S/R reference points See Recommendations G.955, G.956 and G.957. 1.3.18 SDH management subnetwork (SMS) See Recommendation G.784. 1.3.19 SDH physical interface (SPI) See Recommendation G.782. 1.3.20 Section overhead (SOH) See Recommendation G.708. 1.3.21 Synchronous digital hierarchy (SDH) See Recommendation G.707. 1.3.22 Synchronous equipment management function (SEMF) See Recommendation G.782. 1.3.23 Synchronous transport module (STM-N) See Recommendation G.708. 1.3.24 Telecommunications management network (TMN) See Recommendation M.30. styleref head_footRecommendation G.958 PAGE1 2 Applications 2.1 System types Figures 2-1/G.958 and 2-2/G.958 define the reference configurations of the optical line systems specified in this Recommendation and the relationship between Recommendations G.957, G.958 and serie G.780 for their specification. The two following types of applications are identified: 1) inter-office link, (see Figure 2-1/G.958 and S 4.2), 2) intra-office link, (see Figure 2-2/G.958 and S 4.2). These two figures illustrate the fact that Recommendation G.957 specifies the performance of the components of the optical link, from the electro-optic conversion to the opto-electronic one, whereas Recommendation G.958 specifies the performance of the optical link connecting two SDH equipments (multiplexer, digital cross-connect, add-drop multiplexer), including repeaters if any. 2.2 System components A digital line system on optical fibre cables at a given bit rate is usually defined as the means used to implement a digital line section at this bit rate. It comprises line section terminating equipment at both ends, optical fibre sections and regenerators (if needed). The basic frame structure of SDH provides the overhead necessary for the operation and maintenance of line systems, and therefore terminal equipment of synchronous line systems will include multiplexing functions. For example, an STM 4 or STM-16 line system will include a synchronous multiplexer to multiplex the synchronous tributaries. If it is used to implement digital line sections at a given G.702 hierarchy level (e.g. 139 264 kbit/s), it will also include the functions needed to map the plesiochronous tributary into the STM-1. The corresponding functions are described in Recommendation G.783. In order not to constrain equipment design and to ensure compatibility between the various options which may be useful to implement, synchronous line systems are defined for the purpose of this Recommendation as the means used to transport an STM-N stream between the two reference points C of two consecutive synchronous multiplexers (according to the functional description of Recommendation G.783 and assuming that it will also be consistent with future Recommendations on digital cross-connect systems — DXCs). Synchronous line systems therefore comprise the terminating parts of synchronous multiplexers, i.e. from reference point C to reference point A (see Figure 1-1/G.783), the optical fibre sections and the regenerators if needed. These components are described in S 3 (transmission medium), SS 4, 5 and 6 (overall design features, line termination and regenerators). Wherever possible, references to the relevant parts of Recommendations G.782, G.783 and G.784 are made, in particular in terms of functional organization and information flows. This is also illustrated in Figures 2-1/G.958 and 2-2/G.958. FIGURE 2-1/G.958 = 7,5 cm = 293 FIGURE 2-2/G.958 = 9 cm = 352 Note 1 — The figures report functional partitioning, not necessarily physical ones. Note 2 — The functional blocks of Recommendation G.783 are not used because the figures are only intended to describe the scope of the various Recommendations related to Recommendation G.958. Note 3 — A and C are reference points as described in Figure 1-1/G.783. Reference point A is equivalent to S/R reference points of Recommendations G.955 and G.956 (see also Recommendation G.957). PAGE22 styleref head_footRecommendation G.958 3 Type of transmission medium Single mode optical fibre cables conforming to several Recommendations are allowed in these systems. Recommendation G.652 refers to dispersion-unshifted fibres, Recommendation G.653 to dispersion-shifted fibres, and Recommendation G.654 to loss-minimized fibres. Both the attenuation and dispersion aspects are of particular concern to Recommendation G.957; only the latter are currently well defined in these Recommendations. The wavelength regions are around 1310 nm for G.652 fibre, and around 1550 nm for G.652, G.653, and G.654 fibres. Within these regions, the wavelength ranges are defined first by cut-off wavelength and by system attenuation and length requirements. Wavelength ranges are specified in Recommendation G.957 for each application. These fibres may be used with several transmitters; single-longitudinal mode lasers, multi-longitudinal mode lasers, and light-emitting diodes. Spectral characteristics such as chirp, mode-partition noise, and spectral width induce a power penalty, depending upon the fibre dispersion. This will then further limit the operating wavelength ranges. 4 Overall design features 4.1 System design and optical parameters Prior to the advent of SDH the scope of the design of optical line systems included a large number of parameters such as transmit power range, receiver overload and sensitivity, line code, operating wavelength, operation and maintenance features, etc. This led to a great variety of designs, each having a specific combined optimization of the parameters, the only common parameters being the attenuation and dispersion of the optical path between points S and R. Those systems specified in Recommendations G.955 and G.956 provided only longitudinal compatibility, i.e. the possibility of parallel installation on the same cable route. Interconnection between two operators could be achieved either through joint engineering of the optical link, or interconnection at a hierarchical level. (Joint engineering is defined in S 4.3 below.) Synchronous line systems described in this Recommendation are intended to provide transverse compatibility, i.e. the possibility of mixing various manufacturers' equipments within a single optical section. This is based on compliance with bit rates, frame structure and detailed mappings as defined in Recommendations G.707, G.708 and G.709, with general characteristics and functionalities as given in Recommendations G.782 and G.783, and with operation and maintenance as specified in Recommendation G.784. For the optical parameters of the interfaces used in synchronous line systems, transverse compatibility is based on compliance with Recommendation G.957. Recommendation G.957 is summarized in S 4.2. 4.2 Transverse compatibility (Recommendation G.957) Recommendation G.957 (Optical interfaces for equipments and systems relating to the synchronous digital hierarchy), provides specifications for the optical interfaces of SDH equipment, described in Recommendations G.782 and G.783, and line systems described in the present Recommendation, to achieve the possibility of transverse compatibility on elementary cable sections, i.e. mixing various manufacturers' equipments within a single optical section. These specifications also provide longitudinal compatibility with line systems of comparable hierarchical level and application which are in accordance with Recommendations G.955 and G.956. styleref head_footRecommendation G.958 PAGE1 The applications belong to these three categories with regard to the achievable repeater span: — intra-office for distances less than approximately 2 km; — short-haul inter-office for distances of approximately 15 km; — long-haul inter-office for distances of approximately 40 km or more. Within each category further subdivisions are made depending on the fibre type and wavelength region as described in S 3 above. This lea s to one intra- office specification, two inter-office short-haul specifications and three inter office long-haul specifications for each bit rate. For each application separate specifications are given for the transmitter at point S, the receiver at point R and the optical path between S and R. Recommendation G.957 also contains the definition of each parameter used. Corresponding measurement methods are under study and should eventually be included in Recommendation G.957. The relationship between the parameters of the constituents of the optical link is also described in Recommendation G.957 S 5 in order to establish a a common system design approach for engineering SDH optional links. This can be used to select a suitable interface for a given regenerator section, depending on the characteristics of the optical path of this section. It should be noted that the specifications given in Recommendation G.957 are based on worst-case parameter values to provide simple design guidelines for network planners and explicit component specifications for manufacturers. It is recognized that, in some cases, this may lead to more conservative design than could be obtained through joint engineering of the optical link, the use of statistical equipment design approaches (statistical and semi-statistical design approaches are described in Recommendation G.957), or in applications and environments more constrained than those permitted under the standard operating conditions. It is believed that this approach is sufficient to meet the requirements of the great majority of cases. S 4.3 below discusses those cases where there is a need for an improved level of performance. 4.3 Joint engineering For a limited number of cases joint engineering may be envisaged to meet the requirements of optical sections where the interface specifications of Recommendation G.957 prove inadequate. This will probably occur where the required section loss is greater (e.g. 2 dB) than that specified in Recommendation G.957 but may also be considered for other parameters. For those cases it is up to the Administrations/operators concerned to specify more closely the aspects of the system where the specifications of Recommendation G.957 are not satisfactory. It is important to stress that every situation requiring "joint engineering" is likely to be different — hence it is meaningless to try to standardize any of the parameter values for these systems. Instead, it is for the Administrations/operators concerned to come to an agreement as to what is required and then negotiate with manufacturers as to what is actually feasible. This process is very likely to lead to both ends of a transmission link being supplied by the same manufacturer, who meets the required performance by jointly optimizing the transmitters and receivers. PAGE22 styleref head_footRecommendation G.958 It should be pointed out that, in spite of the futility of specifying any parameter values for "jointly engineered" systems, it would be advisable for Administrations/operators or manufacturers involved to follow the general guidelines and system engineering approach used in Recommendation G.957. In particular it would be helpful to use the same parameter definitions as Recommendation G.957 (e.g. receiver sensitivity at R reference point including all temperature and aging effects). 4.4 Pattern dependence testing STM-N signals contain regions within the data stream where the possibility of bit errors being introduced is greater due to the structure of the data within these regions. Three cases in particular may be identified: 1) errors resulting from eye-closure due to the tendency for the mean level of the signal within the equipment to vary with pattern-density due to alternative current couplings ("DC wander"); 2) errors due to failure of the timing recovery circuit to bridge regions of data containing very little timing information in the form of data transitions; 3) errors due to failure of the timing recovery circuit as in 2) above but compounded by the occurrence of the first row of the STM-N section overhead bytes preceding a period of low timing content (these bytes have low data content, particularly for large N). In order to verify the ability of STM-N equipment to operate error-free under the above conditions, a possible method to assess the consecutive identical digit (CID) immunity of a circuit block is presented in Appendix I. This method may be employed during the design phase of the equipment and appropriate points in the production assembly process. 5 Transmission overheads This section describes the regenerator section overhead (RSOH) processing functionality in a synchronous line system. The definition of a regenerator section (see Figure 5-1/G.958 below) and the functional description of a regenerator (see Figure 5-2/G.958 below) are based on the functional block description of Recommendation G.783. The functional blocks and the signals are bi directional where necessary. These descriptions are logical descriptions, not suggested implementations. 5.1 Regenerator section model The regenerator section model is illustrated in Figure 5-1/G.958. The definitions of the functions and signals at reference points are given in Recommendation G.783. A regenerator section is defined as the part of an SDH link between two adjacent reference points C, i.e. where the RSOH is generated and included in the STM-N frame and where the RSOH is extracted from the STM-N frame and terminated. Regenerator section end equipments may be multiplexers (or cross-connect systems) and/or regenerators. In case of intra-office links both ends are multiplexers (or DXCs). styleref head_footRecommendation G.958 PAGE1 FIGURE 5-/1G.958 = 12 cm = 469 5.2 Regenerator model and functionality The regenerator model is shown in Figure 5-2/G.958. The functional blocks and the signals at the reference points are the same as those described in Recommendation G.783, except where noted below. In the following description, signal flows from left to right of Figu e 5- 2/G.958. The signal at reference point A(1) is the STM-N line signal. Reference point A(1) physically corresponds to reference point R in Recommendations G.955 and G.956. The characteristics of the optical signal at this reference point are given in Recommendation G.957. STM-N signal entering at reference point A(1) is electrically regenerated by the SDH physical interface function SPI(1) at reference point B(1). FIGURE 5-2/G.958 = 11,5 cm = 449 SPI(1) converts the signal at reference point A(1) into the sequence of logical levels forming the signal at reference point B(1), for which SPI(1) must grant the characteristics necessary to meet the required transmission and network performance. Transmission performance requirements for synchronous optical systems are given in SS 6 and 7 and the network performance requirements are given in Recommendation G.782. Timing is extracted from the incoming signal and is made available at reference point T1 to the regenerator timing generator (RTG), and at reference point B(1) to the RST(1). RTG requirements are contained in S 6. The status of the received signal is monitored to detect input signal failures. Input signal fail conditions and related parameters are defined in S 7. The signal fail condition is reported to the synchronous equipment management function (SEMF) through reference point S1 and to RST(1) through reference point B(1). The SEMF monitors all the regenerator functions for management and control as described in S 5.2.5. The RST(1) function recovers the frame alignment from the fully formatted and regenerated STM-N data and associated timing at B(1). Criteria for frame alignment algorithm, for out-of-frame condition (OOF), loss of frame state (LOF) and the associated reporting to SEMF through the S2 reference point are described in Recommendation G.783. Then the RST(1) function descrambles the signal at B(1), using the recovered frame alignment and extracts the RSOH bytes. Scrambling in the regenerator is described in S 5.2.1. In an STM-N frame, the use of only a subset of the RSOH bytes is defined. The definitions of these bytes and their positions in the STM-N frame are given in Recommendation G.708 and described in detail for SDH equipment in Recommendation G.783. In this section of Recommendation G.958 features specific to regenerators of synchronous line systems are described. PAGE22 styleref head_footRecommendation G.958 The B1 byte is used to locate faulty regenerator sections. The B1 byte is monitored and the result is reported to SEMF through reference point S2. Byte E1 provides an orderwire voice channel between section terminations. Byte E1 is passed to the overhead access (OHA) function at reference point U1. The OHA function in the regenerator provides the means for accessing specific overhead capacities in RSOH. In the case of a 1:N line protection system, it is not necessary for all regenerators within the same repeater station to access the order-wire signal. The F1 byte is the user channel and is also passed to the OHA function. The access of the user channel in the regenerator is optional. An example of use of the F1 byte to identify a failed section in a chain of regenerator sections is reported in Recommendation G.783. Data communication channels (DCC) bytes D1-D3 are routed to the message communication function (MCF) through reference point N. The use of DCC is described in Recommendations G.783 and G.784. Regenerators should be capable of ignoring the national use bytes and bytes reserved for future international standardization. The RST function might need to access other bytes for medium dependent use (see S 5.2.3 below). The signal at reference point C is an STM-N frame with the associated timing signal. The RST(2) function inserts RSOH bytes to the data at reference point C, performs the scrambling and presents the fully formatted STM-N data to SPI(2) at reference point B(2). The RSOH bytes to be inserted are generated at RST(2), taken either from the OHA through reference point U1 or from the MCF through reference point N, or relayed from RST(1). Under normal operation (i.e. in-frame condition at RST(1)): — A1, A2 and C1 bytes are either generated or relayed. Relaying the received framing bytes reduces the delay in the detection of OOF and recovery from failure in a chain of regenerators. Fault sectionalization capability is not affected because B1 is recalculated for each regenerator section. From a management viewpoint, it is preferable that all the regenerators in a line system conform to either one or other approach; — B1 is generated as described in Recommendation G.783; — E1 and F1 are taken from the OHA; optionally they may be relayed; — D1-D3 are taken from the MCF; — national use bytes and bytes reserved for future international standardization in the RSOH are either relayed or generated as described in Recommendation G.783. When RST(1) is in a failure state described in S 5.2.2: — A1, A2 and C1 are generated; — B1 is generated as described in Recommendation G.783; — E1 and F1 are taken from the OHA; — D1-D3 are taken from the MCF; — national use bytes and bytes reserved for future international standardization in the RSOH are generated as specified in Recommendation G.783. When RST(1) is in OOF condition (but not in a failure state as described in S 5.2.2) all RSOH bytes may be relayed. styleref head_footRecommendation G.958 PAGE1 SPI(2) converts the logical levels of the signal at reference point B(2) into optical pulses at reference point A(2). The SPI function must provide the characteristics of the signal necessary to meet the required transmission and network performance. Reference point A(2) physically corresponds to reference point S in Recommendations G.955 and G.956. The characteristics of the optical signal at this reference point is given in Recommendation G.957. Parameters related to the status of the transmitter are sent to SEMF through reference point S1. Parameters to be monitored are defined in S 7. 5.2.1 Scrambling in the regenerator In order to clearly define the scrambling and descrambling processes, a functional diagram of the signal path in the RST is shown in Figure 5-3/G.958, according to the algorithm reported in Recommendation G.709. The upper part shows the transmission side of RST. Firstly the complete STM-N frame, including B1 byte computed on the previous frame, is built, the STM N frame is then scrambled, except for the first SOH row, i.e. the first N ´ 9 bytes, and finally the BIP-8 is computed over the entire scrambled frame. The BIP-8 value will be included in the next frame as B1 byte. Similarly the central part shows the receive side of RST. Before descrambling, frame alignment is searched or verified on the received STM-N signal and BIP-8 is computed. Then the STM-N frame is descrambled, except for the first SOH row, i.e. the first N ´ 9 bytes, and the RSOH is subsequently used, including B1 byte. The lower part of the Figure 5-3/G.958 shows the entire STM-N frame. This description is only functional, and does not imply any particular physical implementation. The regenerator has to access only the RSOH bytes, and in principle needs to descramble and scramble only these bytes. Therefore data at C to be passed from RST(1) to RST(2) may actually be passed transparently from B(1) to B(2) rather than being descrambled at RST(1) and scrambled at RST(2). 5.2.2 Alarm indication signal (AIS) Under the failure cases mentioned in Recommendation G.783 (i.e. loss of signal or loss of frame), resulting in a logical all ONES signal at reference point C, the signal at C and valid RSOH added at B(2) results in an MS-AIS. Recommendation G.783 specifies the delay to activate and deactivate MS-AIS. 5.2.3 Medium dependent use of overhead bytes It is possible that in the future some bytes may be dedicated to functions specific to a particular transmission medium. These bytes could be taken from those reserved for national use and future international standardization. Otherwise bytes already defined could be modified in their use to include medium specific requirements. As an example the need for and implementation of a function to identify the signal direction in bi-directional optical transmission over a single fibre is for further study. 5.2.4 Intra-office link Reduced functionalities to be used in intra-office link regenerator sections are for further study. 5.2.5 Management The general SDH control and management principles and the interworking with TMN illustrated in Recommendation G.784 apply to the regenerator. The SDH management architecture, the communication network structure among different network elements (NE) and a model for the regenerator are shown in Recommendation G.784. PAGE22 styleref head_footRecommendation G.958 FIGURE 5-3/G.958 = 15,5 cm = 606 The regenerator includes a SEMF. It contains a number of filtering functions that translate primitive information, coming from the functional blocks, to forms usable by the network management and vice versa. Some information is not processed by a filtering function. The filtering functions used in a regenerator are described in detail in Recommendation G.783. The possible use of internal storage for performance parameters history retrieval, the ability of generating autonomous alarm reports on threshold crossings and the possibility of setting externally the threshold values are described in Recommendation G.784. In the regenerator an Agent is present in the SEMF, which controls the exchange of information with other SDH network elements or with the TMN for management purposes. Characteristics of the Agent are given in Recommendation G.784. styleref head_footRecommendation G.958 PAGE1 Messages are sent over the embedded control channel (ECC) that utilizes DCC, i.e. D1-D3 bytes as the physical layer. The protocol stack used and the message generation and termination methods are described in Recommendation G.784. Messages are transmitted and received by the message communication function (MCF), which is connected to the SEMF through V reference point and to a Q interface when provided. Incoming bytes D1-D3 are extracted by the RST function and routed to the MCF through reference point N. Relayed messages and locally generated messages are sent through reference point N as D1-D3 bytes to the RST function, which inserts them into the RSOH of the outgoing STM-N frame. Two interfaces towards elements external to the SDH network may be used. The Q interface can connect the regenerator to an operation system/mediation device (OS/MD). The F interface may be used to connect the regenerator to a workstation for monitoring and maintenance purposes. 5.3 Regenerator interfaces The regenerator has the following interfaces: — S reference point on both transmitting fibres: the interface characteristics at this reference point are specified in Recommendation G.957; — R reference point on both receiving fibres: the interface characteristics at this reference point are specified in Recommendation G.957; — interface for orderwire channel: to be defined; — interface for user channel: to be defined; — use of a Q interface may be foreseen in some applications; — F interface to a workstation: its characteristics are under study. 6 General characteristics of synchronous optical line systems 6.1 Synchronization and timing signal The structure and details of synchronization and timing signals are described in Recommendation G.782. 6.2 Regenerator timing Figure 6-1/G.958 illustrates the timing functions for regenerators. The regenerator timing generator (RTG) includes an internal oscillator. In normal operation, the SPI function recovers the timing from the incoming STM-N signal at reference point A and passes the data and timing to RST at reference point B, and passes the timing signal also to the RTG function at reference point T1. The RTG function provides the timing signal to the outgoing STM-N signal at reference point T0. The directionality of the timing signals is maintained. When transmitting MS-AIS the RTG shall provide timing for the outgoing STM N signal at reference point T0 using the internal oscillator. The long-term frequency stability of the internal oscillator in free-running mode shall be equal to or better than ± 20 ppm. The RTG and SPI functions must accommodate timing from an incoming MS-AIS signal. 6.3 Jitter performance This section deals with jitter requirements for optical interfaces at the STM-N levels as defined in Recommendation G.707. Specifications for multiplex jitter and wander at STM-N and Recommendation G.703 interfaces are described in Recommendations G.782 and G.783. PAGE22 styleref head_footRecommendation G.958 The purpose of the jitter requirements in these sections is to control the accumulation of jitter within SDH line systems. SDH line equipment jitter specifications are organized into limits for the following: jitter generation, jitter transfer and jitter tolerance. 6.3.1 Jitter generation Jitter generation is defined as the amount of jitter at the STM-N output of SDH equipment. An SDH regenerator shall not generate more than 0.01 UI RMS jitter, with no jitter applied at the STM-N input. The measurement bandwidth and technique are under study. 6.3.2 Jitter transfer Jitter transfer specification applies only to SDH regenerators. The jitter transfer function is defined as the ratio of jitter on the output STM-N signal to the jitter applied on the input STM-N signal versus frequency. The jitter transfer function of an SDH regenerator shall be under the curve given in Figure 6-2/G.958, when input sinusoidal jitter up to the mask level in Figure 6-3/G.958 is applied, with the parameters specified for Type A in Table 1/G.958 for each bit rate. FIGURE 6-2/G.958 = 7 cm If an SDH regenerator meets the jitter transfer specification for Type B, it is classified as Type B regenerator. include 958-T01ETABLE 1/G.958 Jitter transfer parameters STM level fc (kHz) P (dB) (type) STM-1 (A) 130 0.1 STM-1 (B) 30 0.1 STM-4 (A) 500 0.1 STM-4 (B) 30 0.1 STM-16 (A) 200 0.1 0 STM-16 (B) 30 0.1 6.3.3 Jitter tolerance Jitter tolerance is defined as the peak-to-peak amplitude of sinusoidal jitter applied on the input STM-N signal that causes a 1 dB optical power penalty at the optical equipment. Note that this is a stress test to ensure that no additional penalty is incurred under operating conditions. This technique is described in Supplement No. 3.8 of the O-Series Recommendations. styleref head_footRecommendation G.958 PAGE1 FIGURE 6-3/G.958 = 7,5 cm = 293 SDH equipment shall tolerate, as a minimum, the input jitter applied according to the mask in Figure 6-3/G.958, with the parameters specified in Table 2/G.958 for each bit rate. In a line system using Type A regenerators, the SDH regenerators and terminal shall meet Type A jitter tolerance specification. In a line system using Type B regenerators, the SDH regenerators and terminals shall meet Type B jitter tolerance specifications. In this case a terminal or regenerators meeting Type A jitter tolerance specifications may also be used. In a line system without regenerators, the SDH terminal shall meet either Type A or Type B jitter tolerance specifications. The use of regenerators of Type A and Type B within the same line system is for further study. include 958-T02ETABLE 2/G.958 Jitter tolerance parameters STM leve (type) ft (kHz) f0 (kHz) A1 (UIp- A2 (UIp- p) p) STM-1 (A) 65 126.5 0.15 1.5 STM-1 (B) 12 121.2 0.15 1.5 STM-4 (A) 250 25 0.15 1.5 STM-4 (B) 12 121.2 0.15 1.5 STM-16 (A) 100 100 0.15 1.5 0 PAGE22 styleref head_footRecommendation G.958 STM-16 (B) 12 121.2 0.15 1.5 styleref head_footRecommendation G.958 PAGE1 6.4 Error performance The synchronous line systems specified in this Recommendation should meet the relevant performance objectives of Recommendation G.821 under the worst environmental conditions. In particular they are required to provide at least error performance in accordance with "section quality classification 1", defined in Recommendation G.821. 6.5 Availability and reliability For further study. 6.6 Environmental conditions For further study. 6.7 Laser safety For safety considerations, according to Reference [1] or national regulations, it may be necessary to provide for an automatic laser shutdown (ALS) facility of the laser in case of cable break. This function is considered as optional. Appendix II shows the required functionality of automatic laser shutdown when implemented. In case automatic laser shutdown facility is implemented the following Command, Configuration & Provisioning information will flow over the S1 reference point (refer to Table 5-12/G.783): include 958-T03E S- Get Set Interfac e S1 ALS implemented ALS enabled/disabled ALS enabled/disabled Tx output on/off Tx output on/off If automatic laser shutdown is implemented it should not impair fault sectionalization capability in case of loss of signal at the transmitter or the receiver due to causes other than a cable break. 7 Operational overview 7.1 Overview The operation, administration and maintenance features of digital synchronous line systems should be designed in accordance with Recommendations M.20 (Maintenance philosophy for telecommunication networks), M.30 (Principles for a telecommunications management network) and G.784 (SDH management). PAGE22 styleref head_footRecommendation G.958 In particular management principles should be based on the concepts defined in Recommendation M.30: — functional organization of management functions (configuration, performance, faults), — functional description of network elements in managed objects. The synchronous line system may be considered from the point of view of management as a SDH Management Sub-network (SMS as defined in Recommendation G.784). The architecture, embedded control channel (ECC) functions, information model and ECC protocols should therefore conform to the specifications given in Recommendation G.784. In particular the information model should follow the specifications given in Recommendation G.784. It should also be noted that synchronous line systems defined in this Recommendation should provide autonomous management functions (performance monitoring, fault location, alarm generation) for early implementations where the connection to a TMN is not possible. The way in which this could be done while retaining forward compatibility with the full deployment of TMN features is for further study. 7.2 General management functions The synchronous line systems should provide the general management functions described in Recommendation G.784. 7.3 Fault (maintenance) management The synchronous line systems should support the fault management functions described in Recommendation G.784. 7.3.1 Alarm surveillance This section describes parameters which should be monitored in the synchronous line systems. In general, these parameters are monitored to assist with fault localization. They are not intended to act as the primary indication of link failure. 7.3.1.1 Parameters to be monitored at the S1 reference point 7.3.1.1.1 Signal status (transmitter) This parameter should indicate whether the transmitter power level is in the range specified in Recommendation G.957 for the defined application code. It will therefore have two values: within range, and out of range. Some form of hysteresis and integration time has to be provided (for further study). It is recognized, that without the use of a coupler and additional detector, the only parameter that can give an indication of the transmitter output power is the current passing through the laser back-facet monitor diode. Under certain fault conditions, the circuit controlling this current may mask significant variations in the laser output power. The exact power level at which this parameter takes on the value "out of range" is not specified. The purpose of monitoring this parameter is to indicate whether a serious fault exists in the transmitter. 7.3.1.1.2 Loss of incoming signal This parameter should take on the value "incoming signal absent" when the incoming power level at the receiver has dropped to a level which is lower than that required to cause a BER of 1 in 10-3. The purpose of monitoring this parameter is to indicate either: i) transmitter failure, ii) optical path break. styleref head_footRecommendation G.958 PAGE1 7.3.1.1.3 Laser bias This parameter should be used to monitor the bias current of the laser of the transmitter. The purpose of monitoring this parameter is to indicate laser degradation well in advance of catastrophic failure of the link. The value at which this parameter takes on the value "bias out of limits" is not specified. 7.3.1.1.4 Laser temperature This parameter can have the values "temperature within range/temperature out of range". The purpose of monitoring this parameter is to indicate failure of the transmitter temperature control circuitry. The value at which this parameter takes on the value "temperature out of range" is not specified. 7.3.1.2 Parameters to be monitored at the S2 reference point The corresponding requirements are contained in Recommendation G.783. 7.3.2 Testing 7.3.2.1 Loopbacks It is considered that the loss of signal indications at the receiver and at the transmitter provide sufficient resolution for practical fault sectionalization and that loopbacks, optical or otherwise, are not necessary. The need for test points or loopbacks for testing purposes is under study. 7.3.3 External events This point concerns the case where there is a need to monitor through the synchronous line system site related alarms (door opening or fire in an unmanned station, etc.) or more generally a non-SDH network element. The corresponding implementation and requirements are under study. 7.4 Performance management The synchronous line systems should support the performance management functions described in Recommendation G.784. These functions should be implemented using information flows at reference points S1 and S2 and filtering functions described in Recommendation G.783. 7.5 TMN interfaces Synchronous line systems should provide at least one interface at each end conforming to Recommendation G.773. 7.6 Orderwire The E1 byte may be used for conferencing between line terminal stations and/or regenerator stations. The E2 byte may be used for express point-to-point communication between terminal stations. The definition of orderwire ports and associated signalling procedures is not in the scope of this Recommendation. PAGE22 styleref head_footRecommendation G.958 APPENDIX I (to Recommendation G.958) Implementation of the cid immunity measurement Summary Alternating digital signal patterns may be used to verify the adequacy of timing-recovery and low-frequency performance of STM-N equipments. Appropriate pattern sequences are defined below and in Figure I-1/G.958. This test does not attempt to simulate conditions which may occur under anomalous operating conditions to which the equipment may be subjected. Description The specific test patterns are made up of consecutive blocks of data of four types: a) all 1s (zero timing content, high average signal amplitude); b) pseudo-random data with a mark-density ratio of 1/2; c) all 0s (zero timing content, low average signal amplitude); d) a data block consisting of the first row of section overhead bytes for the STM-N system under test. The test pattern is shown in Figure I-1/G.958 where the regions A, B, C and D are identified. FIGURE I-1/G.958 = 6,5 cm = 254 styleref head_footRecommendation G.958 PAGE1 The duration of the zero-timing-content periods A and C is made equal to the longest like-element sequences expected in the STM-N signal. A value of 9 bytes (72 bits) is provisionally proposed for this. The duration of the pseudo-random periods should allow recovery of both the zero base line offset of the signal and of the timing recovery circuit following occurrence of the A and C periods. Therefore it should be longer than the longest time constant in the regenerator. In the case of a PLL based clock extraction this could give a value of the order of 10 000 bits. Taking into account possible limitations of test equipment a minimum value of 2000 bits is considered acceptable. The content of the pseudo-random section should be generated by a scrambler having the same polynomial as defined in CCITT Recommendation G.709. Ideally, the scrambler should "free-run" i.e. the beginning of the pattern should be uncorrelated with the frame alignment section. This arrangement will ensure that the system experiences the worst possible phasing of the PRBS at some point during the course of the test. However it is recognized that test equipment limitations may preclude the use of a free running scrambler. Hence it may be necessary to specify a worst-case phasing of the PRBS. This is for further study. The D period is defined as the first row of the section overhead of the STM-N signal, including valid C1 bytes (consecutive binary numbers). It is recommended that this test be applied to SDH systems at any appropriate point in time during the design or production phase. This would be done to demonstrate the ability of both timing-recovery and decision circuits adequately to handle worst-case SDH signals. It should be emphasized that the test pattern may be rejected by or cause malfunction of certain equipments because, for example, the occurrence of the frame alignment bytes within the pattern. The test should therefore only be used for assemblies not so affected, such as timing recovery units, receiver amplifier chains, etc. However, the test may be applicable in certain cases at the available user ports. It is not proposed as a general acceptance test which might require special defined access ports and connection arrangements within the equipment. PAGE22 styleref head_footRecommendation G.958 APPENDIX II (to Recommendation G.958) Description of automatic laser shutdown (ALS) capability in case of cable break FIGURE II-1/G.958 = 5,5 cm =,293 If a cable break happens at point A, the consecutive loss of signal at RX2 is used to cut TX2 which is the adjacent transmitter in the opposite direction. This in turn leads to a loss of signal in RX1 which switches off TX1. For test and monitoring purposes it is possible to override the shutdown mechanism by switching on the laser manually. When the cable has been repaired either an automatic or a manual action according to Figure II-2/G.958, at TX1 or TX2 is necessary to restore correct transmission. The response time of the transmitter/receiver combination, measured from receiver input (point R) to transmitter output (point S) should be less than 0.85 seconds. This response time of 0.85 seconds refers to the time difference between the moment light enters the receiver at point R and the moment the transmitter starts light emitting at point S in case the transmitter is in the shut down situation. "Manual restart" or "Manual restart for test"can only be activated when the laser is shut down. In case 1+1 protection switching is implemented a working channel receiver should shut down a working channel transmitter. Similarly, a protection channel receiver should shut down a protection channel transmitter. styleref head_footRecommendation G.958 PAGE1 FIGURE II-2/G.958 = 23,5 cm = 919 Reference [1] IEC 825 Standard Radiation safety of laser products equipment, classification, requirements and user's guide. PAGE22 styleref head_footRecommendation G.958 IMPORT R:\\ART\\W INTERNATIONAL TELECOMMUNICATION UNION MF\\ITU.WM F \* mergeforma t CCITT G.958 THE INTERNATIONAL TELEGRAPH AND TELEPHONE CONSULTATIVE COMMITTEE DIGITAL NETWORKS, DIGITAL SECTIONS AND DIGITAL LINE SYSTEMS DIGITAL LINE SYSTEMS BASED ON THE SYNCHRONOUS DIGITAL HIERARCHY FOR USE ON OPTICAL FIBRE CABLES Recommendation G.958 IMPORT Geneva, 1990 R:\\ART\\ WMF\\CCIT TRUF.WMF \* mergeform at FOREWORD The CCITT (the International Telegraph and Telephone Consultative Committee) is the permanent organ of the International Telecommunication Union (ITU). CCITT is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis. The Plenary Assembly of CCITT which meets every four years, establishes the topics for study and approves Recommendations prepared by its Study Groups. The approval of Recommendations by the members of CCITT between Plenary Assemblies is covered by the procedure laid down in CCITT Resolution No. 2 (Melbourne, 1988). Recommendation G.958 was prepared by Study Group XV and was approved under the Resolution No. 2 procedure on the 14th of December 1990. ___________________ CCITT NOTE In this Recommendation, the expression "Administration" is used for conciseness to indicate both a telecommunication Administration and a recognized styleref head_footRecommendation G.958 PAGE1 private operating agency. F ITU 1990 All rights reserved. No part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the ITU. PAGE22 styleref head_footRecommendation G.958 styleref head_footRecommendation G.958 PAGE1