ÿWPCL ûÿ2BJ|xÐ ` ÐÐÌÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿH øÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÌÐÐ °°°è ÐÑ Âx„|ü@Ž ÑÐ Å°6Ø'°6Ø'Å Ð5.ÁHÁÓÓÃÃProposed revisions to Recommendation 0.71ÄÄ Áà"ÁIMPULSIVE NOISE MEASURING EQUIPMENT FOR TELEPHONE©TYPE CIRCUITSƒ ÁHÁÃÃReplaceÄÄ existing ÀÀÀÀ 3.1, 3.1.1 and 3.1.2 by: "3.1ÁHÁInput impedance (frequency range 300 Hz to 4 kHz) ÁHÁ©Á  ÁBalanced, earth free Ð  ÐÁHÁ©Á  ÁInput longitudinal interference loss ÃÃ>ÄÄ 46 dB Ð x ÐÁHÁÁ  Á 3.1.1ÁèÁTerminating impedance (other impedances optional) 600 ohms ÁHÁ©Á  ÁReturn loss ÃÃ>ÄÄ 30 dB 3.1.2ÁHÁÃÃHigh impedanceÄÄ approx. 20 kohms ÁHÁ©Á  ÁBridging loss across 300 ohms ÃÃ<ÄÄ 0.15 dB" ÁHÁÃÃAddÄÄ new sentence, table and note at the end of section 3.5.2: ÁHÁ"For measurements of impulsive noise with a 1 020 Hz test signal (see Recommendation 0.6) applied to the circuit under test, a notch filter at 1 020 Hz shall be provided as an option. This filter shall have the following characteristics: ÃÃNoteÄÄ © It should be noted that measurement results may differ if measurements are performed with and without test tone. ÁHÁÃÃReplaceÄÄ section 3.8 with the following text: "3.8ÁHÁÃÃDisplay of measurement resultsÄÄ 3.8.1ÁHÁÃÃImpulsive noise counteÄÄr ÁHÁEach event to be counted shall be recorded as one unit on a counter. The counter shall be able to register at least 999 events. 3.8.2ÁHÁÃÃRelative duration of impulsive noise events (optional)ÄÄ ÁHÁTo allow an easier estimation of data transmission errors which may result from impulsive noise, the instrument shall provide means to calculate and indicate the relative duration of the impulsive noise events. This quantity is the ratio of the time that the input signal exceeds a designated threshold to the total measurement time. Results shall be indicated in a range of 1 x 10Ãé1ÄÄ to 1 x 10Ãé8ÄÄ. 3.8.3ÁHÁÃÃSeconds containing impulsive noise events (optional)ÄÄ ÁHÁAs a further option, the instrument shall provide means to calculate and indicate the percentage of seconds containing one or more occurrences of impulsive noise. Results shall be indicated in a range 0 to 100% with one digit after the decimal point.